# Calibration and Evidence-Locking Policy
|
|
|
|
This document defines when a numerical setting may move from development to a
|
|
locked experiment. Calibration output is engineering evidence, not a paper
|
|
result.
|
|
|
|
## Evidence states
|
|
|
|
Every setting or implementation contract receives one of four states:
|
|
|
|
1. **Verified contract**: a deterministic identity or accounting invariant has
|
|
passed an independent reconstruction from stored arrays.
|
|
2. **Provisional numerical setting**: calibration supports using the setting in
|
|
another calibration or pilot, but not in a locked experiment.
|
|
3. **Frozen setting**: the value, selection rule, analysis configuration, source
|
|
commit, and admissible operating envelope are fixed before locked data are
|
|
inspected.
|
|
4. **Not freeze-ready**: the calibration design is confounded, lacks the
|
|
required comparison, or has an unacceptable safety/transparency trade-off.
|
|
|
|
## Freeze gate
|
|
|
|
A setting can be frozen only if all of the following are true:
|
|
|
|
- trials are generated from a clean, immutable Git commit;
|
|
- paired methods receive identical trajectory, model, sensor, and network
|
|
inputs where the hypothesis requires pairing;
|
|
- calibration instances are genuinely distinct rather than timing-only
|
|
repetitions;
|
|
- failure, invalidity, timeout, clipping, intervention, and exclusion reasons
|
|
are machine-readable and retained;
|
|
- the primary endpoint is numerically well-defined for the selected stratum;
|
|
- the selected value is supported by a parameter scan or an external physical
|
|
calibration, not by a single untested level;
|
|
- tail behavior and failed trials are reviewed before the value is selected;
|
|
- the locked configuration and independent metric configuration receive new
|
|
hashes after the decision.
|
|
|
|
## H1--H4 decision boundaries
|
|
|
|
- **H1**: freeze only after reach clipping, joint-limit stress,
|
|
low-manipulability stress, and valid branch-continuity trajectories are
|
|
separately identifiable. The experimental unit is a complete trajectory.
|
|
- **H2**: numerical calibration may select a robust DLS region, but physical
|
|
wrench-accuracy claims require an independent six-axis F/T reference,
|
|
timestamp calibration, payload/friction calibration, and a causal
|
|
acceleration estimate.
|
|
- **H3**: the fixed-branch virtual-work identity is a deterministic contract.
|
|
Actual closed-loop power mismatch is a different performance endpoint and
|
|
must not be replaced by the identity check. Near-zero-power trials require a
|
|
preregistered normalizer gate or an absolute mismatch outcome.
|
|
- **H4**: passing the energy-accounting audit verifies implementation
|
|
correctness only. Energy capacity and feedback gain remain not freeze-ready
|
|
if the projection distortion is excessive or the tested network/contact
|
|
envelope is incomplete.
|
|
|
|
## Data handling
|
|
|
|
Raw batches remain under `output/experiments/` and are intentionally ignored by
|
|
Git because they can be regenerated from the plan, source commit, and recorded
|
|
seeds. The source-controlled audit records plan hashes, source-data hashes,
|
|
anomalies, and freeze decisions. No calibration value may be copied into the
|
|
manuscript Results section.
|
|
|
|
Locked experiments must use a new batch directory and must never overwrite a
|
|
calibration batch. A locked run is invalid if the worktree is dirty or if its
|
|
recorded source and model hashes do not match the approved lock record.
|